Products
GDI Solutions provide the best technology and services in environmental and safety measurements.
															MSR-Electronic PolyGard® WSB2 non-explosion proof fixed gas detector
PolyGard® WSB2 is a fixed gas detector that senses oxygen, toxic gases, flammable gases, and vapors in spaces without danger of explosion and provides diverse output signals.
The microprocessor-based gas sensor with 4-20 mA output signal and alarm or fault relay is used to monitor the ambient air for combustible gases and vapors by means of a catalytic sensor element. For sensors without LC display, calibration is performed using the handy STL06-PGX2 calibration device or the PC software PCE06-PGX2. Sensors with LC display have an integrated calibration routine that is started from the outside with a permanent magnet without opening the housing. For sensors with LC display the background lighting changes from green to red in the event of an alarm or error.
Features and Benefits
- EC, CAT, IR sensors
 - Standard 4~20mA analog output, RS485 Modbus, Relay
 - Up to 3 different gas sensors can be connected simultaneously
 - Self-Test
 - Three-color lamps and a buzzer based on device status(Optional)
 - Plug-in sensor
 - Remote sensor connection (up to 5 meters)
 - Use of oxygen sensor up to 7 years
 - Convenient maintenance
 - Options for AC or DC power
 - UL61010, EN50271 certified
 
Product Specification
| Category | Description | 
|---|---|
| Size | Type A: 94(W) x 130(H) x 57(D) mm / Type C: 130(W) x 130(H) x 75(D) mm / Type E: 130(W) x 130(H) x 99(D) mm / Sensor: 24(D) x 22(H) mm | 
| Weight | about 330g | 
| Material | Polycarbonate | 
| IP Rating | IP65 | 
| Welding connector | Type A: 2 x M12 or 3 x M20 / Type C&E: 6 x M20 or M25 | 
| Terminal | Screw type terminal, 0.25 ~ 2.5 mm²(power), 0.25 ~ 1.3 mm²(signal) | 
| Display | 2 x 16 characters, 2-color LEDs | 
| Temperature | -30 ~ +60℃(depending on the sensor) | 
| Humidity | 20 ~ 90%RH(non-condensing) | 
| Power supply | 24Vdc+/-20%, 310mA or 100-240Vac, Max.25VA | 
| Buzzer and Lamp | 85dB at 0.1m, 3-color LEDs(Option) | 
| Output | Analog: 4~20mA(3-wire system) / Relay: AL/Fault, 30VAC/DC 0.5A / Digital: RS485 Modbus | 
| Certifications | EMC directives 2014/30/EU / CE EN 61010-1:2010 / EN 50271 / ANSI/UL 61010-1 / CAN/CSA-C22.2 No. 61010-1 | 
SC2 Sensor Specification
| Gas | Measuring range | Sensor | Resolution | 
|---|---|---|---|
| CH4 | 0-100 %LEL | IR | 0.1 %LEL | 
| CH4 | 0-100 %Vol | IR | 0.1 %Vol | 
| C3H8 | 0-100 %LEL | IR | 0.1 %LEL | 
| CO2 | 0-5 %Vol | IR | 0.001 %Vol | 
| CO2 | 0-10 %Vol | IR | 0.01 %Vol | 
| CO2 | 0-5000 ppm | IR | 1 ppm | 
| CH4 | 0-100 %LEL | CAT | 0.1 %LEL | 
| C3H8 | 0-100 %LEL | CAT | 0.1 %LEL | 
| C3H8 | 0-30 %LEL | CAT | 0.01 %LEL | 
| C3H8 | 0-5000 ppm | CAT | 1 ppm | 
| HC | 0-100 %LEL | CAT | 0.1 %LEL | 
| O2(2, 3year lifespan) | 0-25 %Vol | EC | 0.01 %Vol | 
| O2(5, 7year lifespan) | 0-25 %Vol | EC | 0.01 %Vol | 
| CO | 0-150, 250, 300, 500 ppm | EC | 0.1 ppm | 
| H2S | 0-50 ppm | EC | 0.01 ppm | 
| H2S | 0-100, 200, 500 ppm | EC | 0.1 ppm | 
| H2S | 0-1500 ppm | EC | 1 ppm | 
| NH3 | 0-100, 300, 500 ppm | EC | 0.1 ppm | 
| NH3 | 0-1000, 5000 ppm | EC | 1 ppm | 
| NO2 | 0-100 ppm | EC | 0.1 ppm | 
| HCN | 0-50 ppm | EC | 0.01 ppm | 
| HCN | 0-100 ppm | EC | 0.1 ppm | 
| HCl | 0-20 ppm | EC | 0.01 ppm | 
| Formaldehyde | 0-100 ppm | EC | 0.01 ppm | 
| Ethylene | 0-200 ppm | EC | 0.1 ppm | 
| O3 | 0-5 ppm | EC | 0.001 ppm | 
| O3 | 0-10 ppm | EC | 0.01 ppm | 
| Cl2 | 0-10, 20 ppm | EC | 0.01 ppm | 
| SO2 | 0-20 ppm | EC | 0.01 ppm | 
| Ethylene oxide | 0-10 ppm | EC | 0.01 ppm |